When it comes to fire resistance test standards, two commonly referenced standards are BS 476 and BS EN 1363. These standards provide guidance on the performance of construction materials and elements in relation to fire safety. While both standards focus on fire resistance, there are significant differences between them. This article aims to explore and compare BS 476 and BS EN 1363.
BS 476: Fire tests on building materials and structures
BS 476 is a British Standard that has been used for testing the fire performance of construction products since 1971. It consists of several parts, each covering different aspects of fire testing. Part 20, for example, focuses on the determination of the fire resistance of timber door assemblies. Part 22 covers methods for determining the contribution of fire-resisting and non-fire-resisting elements of construction to the fire resistance of a structure.
BS 476 tests measure various properties of materials, such as the time taken for a material or element to reach certain temperature thresholds or collapse under fire conditions. It provides a classification system based on the test results, categorizing materials as either non-combustible, limited combustibility, or classed according to their fire resistance.
BS EN 1363: Fire resistance tests for elements of construction
BS EN 1363, on the other hand, is a European Standard that specifies methods for determining the fire resistance of various structural elements within a building. The standard provides requirements for assessing the ability of elements to withstand exposure to fire for a specific duration without losing their load-bearing capacity, integrity, or thermal insulation.
The tests specified by BS EN 1363 involve subjecting the elements to controlled heating conditions. The duration of the test varies depending on the intended application of the element being tested. The standard also defines criteria for measuring and classifying fire resistance based on parameters such as stability, integrity, and insulation properties.
Differences between BS 476 and BS EN 1363
The main difference between BS 476 and BS EN 1363 lies in their scope and applicability. BS 476 focuses more on individual materials and their contribution to the fire resistance of structures, whereas BS EN 1363 concentrates on testing and classifying the fire resistance of specific structural elements within a building.
Another notable difference is that while BS 476 is a British Standard, BS EN 1363 is a European Standard. As a result, BS EN 1363 is recognized and used across many European countries, while BS 476 may mainly be applicable in the UK and some other regions.
In conclusion, BS 476 and BS EN 1363 are both important standards for evaluating the fire resistance of construction materials and elements. While they have common objectives, they differ in their focus, scope, and geographical applicability. Understanding these differences is crucial for manufacturers, architects, and regulatory bodies when it comes to ensuring adequate fire safety measures in buildings.
Contact: Eason Wang
Phone: +86-13751010017
Tel: +86-755-33168386
Add: 1F Junfeng Building, Gongle, Xixiang, Baoan District, Shenzhen, Guangdong, China