NO | Figure No. | Description |
1 | CEE7/C1 | 10/16A 250V two-pole socket-outlets Gauges c1 for size of entry holes for plug pins |
2 | CEE7/C2A.B | 10/16A 250V two-pole socket-outlets and two-pole plugs with pin-type earthing-contact Gauges c2 for minimum opening of contact tubes |
3 | CEE7/C3 | 10/16A 250V two-pole socket-outlets Gauge c3 for acceptance of two-pole plugs |
4 | CEE7/C4 | 10/16A 250V two-pole socket-outlets with side earthing-contacts Gauge c4 for acceptance of two-pole plugs with side earthing contacts |
5 | CEE7/C6A.B | 10/16A 250V two-pole fixed socket-outlets Gauges c6 for fixing holes or slots |
6 | CEE7/C7A.B.C.D | 10/16A 250V two-pole socket-outlets Gauges c7 for distance to point of first contact |
7 | CEE7/C8 | 10/16A 250V two-pole socket-outlets Gauge c8 for wiring channel |
8 | CEE7/C9A.B | 2.5A 250V and 10/16A250V two-pole plugs and 10/16A 250V two-pole socket-outlets with pin-type earthing-contact Gauges c9 for pin diameter |
9 | CEE7/C10A.B | 10/16A 250Vtwo-pole plugs Gauges c10 for pin spacing |
10 | CEE7/C11 | 10/16A 250V two-pole socket-outlets and two-pole plugs with pin-type earthing-contact Gauge c11 for maximum opening of contact tubes |
11 | CEE7/C12 | 10/16A 250V two-pole plugs with side earthing-contacts Gauge c12 for interchangeability |
12 | CEE7/C13 | 2.5A 250V two-pole plugs for class ii appliances Gauge for interchangeability |
13 | CEE7/C14 | 10/16A 250V two-pole flush-type socket-outlets for screw fixing Gauge for dimensions of mounting boxes |
14 | CEE7/C15 | 10/16A 250V two-pole plugs without earthing contact Gauge for non-interchangeability with two-pole plugs with earthing contact |
15 | CEE7/C16 | 10/16A 250V two-pole socket-outlets with side earthing-contacts Gauge for non-acceptance of two-pole plugs wihout earthing contact |
16 | CEE7/C18 | 10/16A 250V two-pole socket-outlets without earthing contact Gauge for checking impossibility of single-pole insertion of plugs |
17 | CEE7/C19A.B.C | 2.5A 250V and 10/16A 250V two-pole plugs |
Gauges for checking impossibility of single-pole insertion of plugs into socket-outlets | ||
18 | CEE7/C19a | 2.5A 250V and 10/16A 250V two-pole plugs Gauges for checking impossibility of single-pole insertion of plugs into socket-outlets |
19 | CEE7/C20 | Device for testing non-solid pins |
20 | CEE7/C21 | Device for checking the resistance to lateral strain of 10/16A 250V two-pole fixed socket-outlets |
21 | CEE7/C22 | Splash apparatus |
22 | CEE7/C23 | Device for measuring the contact pressure of earthing contacts of 10/16A 250V two-pole socket-outlets with side earthing-contacts |
23 | CEE7/C24 | Apparatus for breaking capacity and normal operation tests |
24 | CEE7/C25 | Circuit diagrams for breaking capacity and normal operation tests |
25 | CEE7/C26 | Apparatus for checking the withdrawal force |
26 | CEE7/C27 | Apparatus for testing the cord anchorage |
27 | CEE7/C28 | Apparatus for flexing test |
28 | CEE7/C29 | Impact-test apparatus |
29 | CEE7/C30 | Tumbling barrel |
30 | CEE7/C31 | Apparatus for impact test at low temperature |
31 | CEE7/C32 | Arrangement for compression test |
32 | CEE7/C33 | Apparatus for abrasion test on insulating collars of plug pins |
33 | CEE7/C34 | Ball-pressure apparatus |
34 | CEE7/C35 | Apparatus for pressure test on plugs and portable socket-outlets |
35 | CEE7/C36 | Hot mandrel apparatus |
36 | CEE7/C37 | Arrangement and dimensions of the electrodes for the tracking test |
37 | CEE7/C104 | |
38 | CEE7/C105/C1A | |
39 | CEE7/C106/C3A | |
40 | IEC 60884-Fig9 | Gauge for checking non-accessibility of live parts, through shutters |
41 |
IEC 60884-Fig10 |
Gauge for checking non-accessibility of live parts, through shutters and of live parts of socket-outlets with increased protection |
Contact: Eason Wang
Phone: +86-13751010017
Tel: +86-755-33168386
Add: 1F Junfeng Building, Gongle, Xixiang, Baoan District, Shenzhen, Guangdong, China